locksmith riverside key maker

1994-1997 Cadillac Deville Keyless Entry Remote Programming Instructions

 Step-by-Step How To Programming & Memory Clearing Instructions for a 1994-1997 Cadillac Deville Keyless Entry Remote Fob

Verify that this important information is on the back of your remote before using these programming instructions.

FCC ID: ABO1602T
Factory Part No: 16259829, 16196066, 16259819, 16183016

Programming Notes:
Obtain all remote transmitters for this vehicle. 

This procedure will erase all previously programmed remotes.

You must program all existing and new remotes that you wish to use on the vehicle at this time.


Step-by-Step How To Programming Instructions:


Use these Instructions if your Deville has an Analog Instrument Cluster 

Press OFF and WARM buttons on  Climate Control Panel (CCP) simultaneously. 

(Instrument Panel Cluster (IPC) will light all telltales, then go blank) System is now in diagnostic mode.

Press PASSENGER COOLER button until “RFA” is displayed, then press FAN UP. 

If   “RFA DATA” is displayed, press FAN DOWN.

If   “RFA OVERRIDE” is displayed, press FAN UP.

If  “RFA 500 NO OVERRIDE” is displayed, press FAN DOWN.


If  “RFA 501 PROGRAM FOB #1” is displayed, Press FAN UP.

IPC will show “0” on right side of Driver Information Center (DIC) display.


Press warmer button on climate control unit until “99” is displayed.

Press and hold TRUNK button on transmitter.


While holding TRUNK button, press LOCK button and hold for one second. 

Hold both buttons for a total of 3 seconds.

Locks cycle when programming is complete (if remote is not programmed within 30 seconds after entering “99” override display, system will default and you must begin again at Step 2.

To program a second remote, press FAN DOWN button until  “RFA 502 PROGRAM FOB #2” is displayed, then press FAN UP.  Repeat Step 4.


To exit system, press AUTO, MODE UP, MODE DOWN, or RESET.


Test all remotes.



Use these Instructions if your Deville has a Digital Instrument Cluster

Press OFF and WARM buttons on Climate Control Center (CCC) simultaneously.

Instrument Panel Cluster (IPC) will light all telltales, go blank then  enter DIAGNOSTICMODE.

Press FAN DOW button to scroll through system until “RFA” is displayed, then press FAN UP button.

Press FAN DOWN button until “RFA OVERRIDE” is displayed, then press FAN UP button.

When  “NO OVRD RF 500” is displayed, then press FAN UP button.

When “PGM FOBL 501” is displayed, press WARM button and “99” will be displayed in left upper corner of IPC just below odometer.


System is now ready to program remote.

Press and hold TRUNK button on transmitter.


While holding TRUNK button, press LOCK button and hold for one second.

Hold both buttons for a total of 3 seconds.

Locks cycle when programming is complete (if remote is not programmed within 30 seconds after entering “99” override display, system will default and you must begin again at Step 2.)

To program second remote, pres FAN UP button until “PGM FOB2 502” is displayed, then follow steps 2 and 3 toprogram second remote.


To exit system, press RECIRC or RESET buttons.


Test all remotes.

Programming is complete.

1994-1997 Cadillac Deville remote

Locksmith riverside ca